A conduit has the following conductors installed:

Two (2) phase wires and the neutral of a 4-wire, 3-phase wye-connected system.

Three (3) phase conductors and the neutral of a 4-wire, 3-phase wye-connected system supplying a nonlinear load.

Based upon the total number of current-carrying conductors, the allowable ampacity of each conductor as determined in 310.15.C.1 in 2022 NEC must be adjusted by:
View this question
When will a conductor with type USE-2 insulation have an operating temperature of  90 Degrees C?

I. when used in dry and wet locations

II. when used in wet locations only

0%
100%
0%
View this question
Where only (2) two conductors are installed in a conduit or tubing, the total cross-sectional area of the conductors are not to exceed ______________ the cross-sectional area of the conduit.
View this question
What is the correction factor for an Aluminum conductor type SIS when installed in a 130-degree F ambient room?
0%
0%
0%
0%
View this question
Where bare or covered conductors are used with insulated conductors, the temperature rating of the bare or covered conductor shall be __________________  for the purpose of determining its ampacity.
0%
0%
0%
0%
View this question
The maximum number of #10 THW conductors that can be installed in a 1 inch EMT conduit is:
View this question
Circuit conductors shall be permitted to connected in parallel (electrically joined at both ends) only in sizes 1/0 and  ____ where installed in accordance with 310.(H)(2) through (H)(6).
0%
0%
View this question
Each of (8) current-carrying, single insulated, type THW, # 4  Copper conductors in a raceway installed in an ambient temperature of 42 degrees C would have a maximum allowable ampacity of:
0%
0%
100%
View this question
NEC 334.80 requires that NM cables that are bundled together and pass through wood framing members and are fire-caulked, the allowable ampacity of each conductor must be adjusted. What would be the adjusted ampacity of the individual conductors of four 12-2 wg NM cables?
0%
0%
0%
0%
View this question
Unless specifically required in specific parts of the NEC, what is the maximum size solid conductor permitted to be installed in a raceway? Hint: Article 310 covers Conductors for General Wiring and has multiple tables involving ampacities, properties and sizes of conductors)
0%
0%
0%
0%
View this question